Standard Adsorber Filters (F652 - F654)
 
FEATURES
Protects end processes from gaseous oil contamination and rids compressed air of offensive oily odors.
Removes hydrocarbons for use in analytical instruments.
Low pressure drop.
Pop-up indicator indicates abnormal condition such as plugged element or excessive flow. Critical protection requires changing element at regular intervals.
6 oz. black coated metal bowl with liquid level sight
Black coated aluminum housing.
Manual drain.
In-line or modular installation.

OPTIONS
For Metal Bowl without sight delete W

SPECIFICATIONS
Metal Bowl
Zinc, black coated
Max. pressure 250 psig
Operating temperature range 40°F to 200°F

Metal Bowl with Sight
Zinc black coated
Max. pressure 250 psig
Operating temperature range 40°F to 160°F

Element
Multi-wrapped layers of impregnated activated charcoal particles to increase purification qualities. If the compressed air has been prepared by a suitable refrigerated dryer and F5A Oilescer filter, the F6 Absorber will insure oil concentrations of .0015 PPM by weight. In all cases, an F5 Oilescer must precede an F6 Absorber. To prevent any particle migration downstream an F3 with 3 micron element should be installed downstream for total system protection.

Body:   Black coated aluminum
Baffle:   Plastic
Seals:   Buna N

Bowl Kits
Metal bowl without sight  (BKF45M)
Metal bowl with sight  (BKF45W)

Element Kits
Charcoal wrapped 2-pack  (EK65)  Clear net no color

Repair Kits
Repair kit  (RKF45)
Replacement sight kit  (WK35)
Indicator Pop-up kit  (DPK-05)

Mounting Bracket
FBK5

APPLICATIONS
Food plants
Pharmaceutical
Instrumentation